Parameters
List of parameters
r3132
CO: Actual component number / Act comp_no.
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the component number of the oldest fault that is still active.
Dependency:
Refer to: r2131, r3131
p3230[0...n]
CI: Load monitoring speed actual value / Load monit n_act
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for the speed actual value of the load monitoring.
Dependency:
Refer to: r2169, p2181, p2192, p2193, p3231
Refer to: A07920, A07921, A07922, F07923, F07924, F07925
Note:
The parameter is only effective for p2193 = 2.
p3231[0...n]
Load monitoring speed deviation / Load monit n_dev
Access level: 3
Can be changed: U, T
Units group: 3_1
Min
0.00 [rpm]
Description:
Sets the permissible speed deviation during load monitoring (for p2193 = 2).
Dependency:
Refer to: r2169, p2181, p2193, p3230
Refer to: A07920, A07921, A07922, F07923, F07924, F07925
p3232[0...n]
BI: Load monitoring failure detection / Load_moni fail_det
Access level: 3
Can be changed: U, T
Units group: -
Min
-
Description:
Sets the signal source for detecting a failure.
Dependency:
Refer to: p2192, p2193
Refer to: F07936
Note:
Monitoring is triggered with a 0 signal, as soon as the time in p2192 has expired.
p3233[0...n]
Torque actual value filter time constant / M_act_filt T
Access level: 3
Can be changed: U, T
Units group: -
Min
0 [ms]
Description:
Sets the time constant for the PT1 element to smooth the torque actual value.
The smoothed torque actual value is compared with the threshold values and is only used for messages and sig-
nals.
1-372
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: p0505
Max
210000.00 [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
1000000 [ms]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Integer32
Dyn. index: -
Func. diagram: 8060
Factory setting
-
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 8013
Factory setting
0
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
150.00 [rpm]
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 8013
Factory setting
1
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 8013
Factory setting
100 [ms]