Siemens SINAMICS G120D List Manual page 167

Hide thumbs Also See for SINAMICS G120D:

Advertisement

p1136[0...n]
OFF3 initial rounding-off time / RFGOFF3 t_strt_rnd
Access level: 3
Can be changed: U, T
Units group: -
Min
0.000 [s]
Description:
Sets the initial rounding-off time for OFF3 for the extended ramp generator.
p1137[0...n]
OFF3 final rounding-off time / RFG OFF3 t_end_del
Access level: 3
Can be changed: U, T
Units group: -
Min
0.000 [s]
Description:
Sets the final rounding-off time for OFF3 for the extended ramp generator.
p1138[0...n]
CI: Up ramp scaling / Up ramp scaling
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for scaling the up ramp.
Dependency:
Refer to: p1120
Note:
The ramp-up time is set in p1120.
p1139[0...n]
CI: Down ramp scaling / Down ramp scaling
Access level: 3
Can be changed: T
Units group: -
Min
-
Description:
Sets the signal source for scaling the down ramp.
Dependency:
Refer to: p1121
Note:
The ramp-down time is set in p1121.
p1140[0...n]
BI: Enable ramp-function generator/inhibit ramp-function generator / RFG enable
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source for the command "enable ramp-function generator/inhibit ramp-function generator".
For the PROFIdrive profile, this command corresponds to control word 1 bit 4 (STW1.4).
BI: p1140 = 0 signal:
Inhibits the ramp-function generator (the ramp-function generator output is set to zero).
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
30.000 [s]
Calculated: -
Scaling: -
Unit selection: -
Max
30.000 [s]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3070
Factory setting
0.000 [s]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3070
Factory setting
0.000 [s]
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 3060, 3070
Factory setting
1
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 3060, 3070
Factory setting
1
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 2501
Factory setting
[0] 2090.4
[1] 1
[2] 2090.4
[3] 2090.4
1-167