Dependency:
Only the unit of the technology controller parameters are switched over (unit group 9_1).
Refer to: p0596
Note:
When switching over from % into another unit, the following sequence applies:
- set p0596
- set p0595 to the required unit
p0596
Technological unit reference quantity / Tech unit ref qty
CU240D-2_DP
Access level: 1
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0.01
Description:
Sets the reference quantity for the technological units.
When changing over using changeover parameter p0595 to absolute units, all of the parameters involved refer to
the reference quantity.
Dependency:
Refer to: p0595
Notice:
When changing over from one technological unit into another, or when changing the reference parameter, a
changeover is not made.
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
ltr/min
m³/min
ltr/h
m³/h
kg/s
kg/min
kg/h
t/min
t/h
N
kN
Nm
psi
°F
gallon/s
inch³/s
gallon/min
inch³/min
gallon/h
inch³/h
lb/s
lb/min
lb/h
lbf
lbf ft
K
rpm
parts/min
m/s
ft³/s
ft³/min
BTU/min
BTU/h
mbar
inch wg
ft wg
m wg
% r.h.
g/kg
Calculated: -
Scaling: -
Unit selection: -
Max
340.28235E36
Parameters
List of parameters
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
1.00