r2130[0...63]
Fault time received in days / t_fault recv days
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the system runtime in days when the fault occurred.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2133, r2136
Notice:
The time comprises r2130 (days) and r0948 (milliseconds).
The value displayed in p2130 refers to 01.01.1970.
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2131
CO: Actual fault code / Actual fault code
Access level: 2
Can be changed: -
Units group: -
Min
-
Description:
Displays the code of the oldest active fault.
Dependency:
Refer to: r3131, r3132
Note:
0: No fault present.
r2132
CO: Actual alarm code / Actual alarm code
Access level: 2
Can be changed: -
Units group: -
Min
-
Description:
Displays the code of the last alarm that occurred.
Note:
0: No alarm present.
r2133[0...63]
Fault value for float values / Fault val float
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays additional information about the fault that occurred for float values.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2136
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2134[0...63]
Alarm value for float values / Alarm value float
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays additional information about the active alarm for float values.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2145, r2146
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Parameters
List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: 8060
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: 8060
Factory setting
-
Data type: Unsigned16
Dyn. index: -
Func. diagram: 8065
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 8060
Factory setting
-
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 8065
Factory setting
-