Parameters
List of parameters
r20232
BO: LIM 0 input quantity at the upper limit QU / LIM 0 QU
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter of instance LIM 0 of limiter QU (upper limit reached), i.e. QU = 1 for X >= LU.
r20233
BO: LIM 0 input quantity at the lower limit QL / LIM 0 QL
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter of instance LIM 0 of limiter QL (lower limit reached), i.e. QL = 1 for X <= LL.
p20234
LIM 0 run-time group / LIM 0 RTG
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
5
Description:
Setting parameter for the run-time group in which instance LIM 0 of the limiter is to be called.
Value:
5:
6:
9999: Do not calculate
p20235
LIM 0 run sequence / LIM 0 RunSeq
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0
Description:
Setting parameter for the run sequence of instance LIM 0 within the run-time group set in p20234.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20236
CI: LIM 1 input X / LIM 1 input X
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source of input quantity X of instance LIM 1 of the limiter.
1-510
Run-time group 5
Run-time group 6
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
9999
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7260
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7260
Factory setting
-
Data type: Integer16
Dyn. index: -
Func. diagram: 7260
Factory setting
9999
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7260
Factory setting
640
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 7260
Factory setting
0