Siemens SINAMICS G120D List Manual page 144

Hide thumbs Also See for SINAMICS G120D:

Advertisement

Parameters
List of parameters
11:
13:
16:
30:
31:
33:
36:
60:
61:
63:
66:
Dependency:
When changing this parameter, the following settings are influenced:
Refer to: p1070, p1071, p1075, p1076
Caution:
If p1000 is selected as the main setpoint of the fieldbus, the following BICO interconnection is set automatically:
p2051[1] = r0063
Caution:
When executing a specific macro, the corresponding programmed settings are made and become active.
Notice:
The parameter is possibly protected as a result of p0922.
For PROFIBUS/PROFINET Control Units, the following applies: The parameter can be freely set by setting p0922 =
999.
p1001[0...n]
CO: Fixed speed setpoint 1 / n_set_fixed 1
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 1.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1002[0...n]
CO: Fixed speed setpoint 2 / n_set_fixed 2
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 2.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
p1003[0...n]
CO: Fixed speed setpoint 3 / n_set_fixed 3
Access level: 2
Can be changed: U, T
Units group: 3_1
Min
-210000.000 [rpm]
Description:
Sets a value for the fixed speed / velocity setpoint 3.
Dependency:
Refer to: p1020, p1021, p1022, p1023, r1024, r1197
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
1-144
Motor potentiometer + motor potentiometer
Motor potentiometer + fixed speed setpoint
Motor potentiometer + fieldbus
Fixed speed setpoint + no main setpoint
Fixed speed setpoint + motor potentiometer
Fixed speed setpoint + fixed speed setpoint
Fixed speed setpoint + fieldbus
Fieldbus + no main setpoint
Fieldbus + motor potentiometer
Fieldbus + fixed speed setpoint
Fieldbus+fieldbus
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
210000.000 [rpm]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 1021, 3010
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3010
Factory setting
0.000 [rpm]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 3010
Factory setting
0.000 [rpm]