Parameters
List of parameters
250:
270:
290:
300:
Note:
Re r0047 = 300:
This value is also displayed if encoder calibration p1990 is selected.
r0050.0...1
CO/BO: Command Data Set CDS effective / CDS effective
Access level: 3
Can be changed: -
Units group: -
Min
-
Description:
Displays the effective Command Data Set (CDS).
Bit field:
Bit
Signal name
00
CDS eff. bit 0
01
CDS eff. bit 1
Dependency:
Refer to: p0810, p0811, r0836
Note:
The Command Data Set selected using a binector input (e.g. p0810) is displayed using r0836.
r0051.0...1
CO/BO: Drive Data Set DDS effective / DDS effective
Access level: 2
Can be changed: -
Units group: -
Min
-
Description:
Displays the effective Drive Data Set (DDS).
Bit field:
Bit
Signal name
00
DDS eff. bit 0
01
DDS eff. bit 1
Dependency:
Refer to: p0820, p0821, r0837
Note:
When selecting the motor data identification routine and the rotating measurement, the drive data set changeover is
suppressed.
r0052.0...15
CO/BO: Status word 1 / ZSW 1
Access level: 2
Can be changed: -
Units group: -
Min
-
Description:
Display and connector output for status word 1.
Bit field:
Bit
Signal name
00
Rdy for switch on
01
Ready
02
Operation enabled
03
Fault present
04
Coast down active (OFF2)
05
Quick Stop active (OFF3)
06
Switching on inhibited active
07
Alarm present
08
Deviation setpoint/actual speed
09
Control request
10
Maximum speed reached
11
I, M, P limit reached
12
Motor holding brake open
1-34
Identification stator inductance LQLD
Identification stator resistance
Identification valve lockout time
Stationary measurement selected
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
ON
ON
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
ON
ON
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
No
No
Yes
Yes
No
Yes
Yes
No
Yes
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned8
Dyn. index: -
Func. diagram: 8560
Factory setting
-
0 signal
OFF
OFF
Data type: Unsigned8
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
OFF
OFF
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
No
No
No
Yes
Yes
No
No
Yes
No
No
Yes
No
FP
-
-
FP
-
-
FP
-
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement

loading

This manual is also suitable for:

Cu240d-2Cu250d-2Cu240d-2 dpCu240d-2 dp fCu240d-2 pnCu240d-2 pn f ... Show all