List of parameters
p9342
SI Motion act. val. comparison tolerance (crossw.) (processor 2) / SI Mtn actV tol P2
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: C(95)
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
0.0010 [°]
Description:
Sets the tolerance for the crosswise data comparison of the actual position between processors 1 and 2.
Dependency:
Refer to: p9542
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
For a linear axis, the tolerance is internally limited to 10 mm.
For a "linear axis with rotating motor" and standard setting of p9320, p9321 and p9322, the standard setting of
p9342 corresponds to a position tolerance of 36 ° on the motor side.
p9344
SI Motion actual value comparison tolerance (referencing) (MM) / SI mtn ref tol MM
Access level: 3
Can be changed: C(95)
Units group: -
Min
0.0000 [mm]
Description:
Sets the tolerance to check the actual values after referencing (incremental encoder) or when powering up (abso-
lute encoder).
Dependency:
Refer to: C01711
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
For linear axes, the maximum value is limited to 1mm.
p9345
SI Motion SSM filter time (processor 2) / SI Mtn SSM filt P2
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: C(95)
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
0.00 [µs]
Description:
Sets the filter time for the SSM feedback signal to detect standstill.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
The filter time is effective only if the function is enabled (p9301.16 = p9501.16 = 1).
The parameter is included in the crosswise data comparison of the two monitoring channels.
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
p9346
SI Motion SSM velocity limit (processor 2) / SI Mtn SSM v_limP2
CU240D-2_DP_F
Access level: 3
CU240D-2_PN_F
Can be changed: C(95)
CU250D-2_DP_F
Units group: -
CU250D-2_PN_F
Min
0.00 [rpm]
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill (n < nx).
When this limit value is undershot, the signal "SSM feedback signal active" is set.
Dependency:
Refer to: p9546
1-404
Calculated: -
Scaling: -
Unit selection: -
Max
360.0000 [°]
Calculated: -
Scaling: -
Unit selection: -
Max
36.0000 [mm]
Calculated: -
Scaling: -
Unit selection: -
Max
100000.00 [µs]
Calculated: -
Scaling: -
Unit selection: -
Max
100000.00 [rpm]
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
12.0000 [°]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
0.0100 [mm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2823
Factory setting
0.00 [µs]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 2823
Factory setting
20.00 [rpm]