Parameters
List of parameters
p20311
ADD 2 run sequence / ADD 2 RunSeq
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
0
Description:
Setting parameter for the run sequence of instance ADD 2 within the run-time group set in p20310.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20312[0...1]
CI: NCM 0 inputs / NCM 0 inputs
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source of input quantities X0 and X1 of instance NCM 0 of the numeric comparator.
Index:
[0] = Input X0
[1] = Input X1
r20313
BO: NCM 0 output QU / NCM 0 output QU
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter for binary quantity QU of instance NCM 0 of the numeric comparator.
QU is only set if X0 > X1.
r20314
BO: NCM 0 output QE / NCM 0 output QE
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter for binary quantity QE of instance NCM 0 of the numeric comparator.
QE is only set if X0 = X1.
r20315
BO: NCM 0 output QL / NCM 0 output QL
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Display parameter for binary quantity QL of instance NCM 0 of the numeric comparator.
QL is only set if X0 < X1.
1-524
Calculated: -
Scaling: -
Unit selection: -
Max
32000
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: Unsigned16
Dyn. index: -
Func. diagram: 7220
Factory setting
800
Data type: U32 / FloatingPoint32
Dyn. index: -
Func. diagram: 7225
Factory setting
0
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7225
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7225
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7225
Factory setting
-