List of parameters
p2223[0...n]
BI: Technology controller fixed value selection bit 3 / Tec_ctrl sel bit 3
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: T
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Sets the signal source to select the fixed value of the technology controller.
Dependency:
Refer to: p2220, p2221, p2222
r2224
CO: Technology controller fixed value effective / Tec_ctr FixVal eff
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: 9_1
CU240D-2_PN_F
Min
- [%]
Description:
Displays the selected and effective fixed value of the technology controller.
Dependency:
Refer to: r2229
r2225.0
CO/BO: Technology controller fixed value selection status word / Tec_ctr FixVal ZSW
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Displays the status word for the fixed value selection of the technology controller.
Bit field:
Bit
Signal name
00
Technology controller fixed value selected
r2229
Technology controller number actual / Tec_ctrl No. act
CU240D-2_DP
Access level: 3
CU240D-2_DP_F
Can be changed: -
CU240D-2_PN
Units group: -
CU240D-2_PN_F
Min
-
Description:
Displays the number of the selected fixed setpoint of the technology controller.
Dependency:
Refer to: r2224
1-302
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: PERCENT
Unit selection: p0595
Max
- [%]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
© Siemens AG 2012 - 2013 All Rights Reserved
SINAMICS G120D List Manual (LH14), 01/2013
Data type: U32 / Binary
Dyn. index: CDS, p0170
Func. diagram: 7950
Factory setting
0
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 7950
Factory setting
- [%]
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
0 signal
No
Data type: Unsigned32
Dyn. index: -
Func. diagram: 7950
Factory setting
-
FP