φ
Compare
match signal
Counter
clear signal
TCNT
TGR
Figure 10.34 Counter Clear Timing (Compare Match)
φ
Input capture
signal
Counter clear
signal
TCNT
TGR
Buffer Operation Timing: Figures 10.36 and 10.37 show the timings in buffer operation.
φ
TCNT
Compare
match signal
TGRA,
TGRB
TGRC,
TGRD
Figure 10.36 Buffer Operation Timing (Compare Match)
Rev. 2.00, 05/03, page 440 of 820
N
N
N
Figure 10.35 Counter Clear Timing (Input Capture)
n
n
N
H'0000
H'0000
N
n + 1
N