TCNT value
H'0180
H'0160
H'0010
H'0005
H'0000
TIOCA
TGRA
TIOCB
TGRB
10.4.2

Synchronous Operation

In synchronous operation, the values in multiple TCNT counters can be rewritten simultaneously
(synchronous presetting). Also, multiple of TCNT counters can be cleared simultaneously
(synchronous clearing) by making the appropriate setting in TCR.
Synchronous operation enables TGR to be incremented with respect to a single time base.
Channels 0 to 5 can all be designated for synchronous operation.
Example of Synchronous Operation Setting Procedure: Figure 10.10 shows an example of the
synchronous operation setting procedure.
Rev. 2.00, 05/03, page 416 of 820
H'0005

Figure 10.9 Example of Input Capture Operation

Counter cleared by TIOCB
input (falling edge)
H'0160
H'0180
Time
H'0010