Serial Data Reception (Clocked Synchronous Mode); Figure 14.18 Example Of Sci Operation In Reception - Renesas H8S/2368 Series Hardware Manual

16-bit single-chip microcomputer
Table of Contents

Advertisement

14.6.4

Serial Data Reception (Clocked Synchronous Mode)

Figure 14.18 shows an example of SCI operation for reception in clocked synchronous mode. In
serial reception, the SCI operates as described below.
1. The SCI performs internal initialization in synchronization with a synchronization clock input
or output, starts receiving data, and stores the received data in RSR.
2. If an overrun error (when reception of the next data is completed while the RDRF flag is still
set to 1) occurs, the ORER bit in SSR is set to 1. If the RIE bit in SCR is set to 1 at this time,
an ERI interrupt request is generated. Receive data is not transferred to RDR. The RDRF flag
remains to be set to 1.
3. If reception finishes successfully, the RDRF bit in SSR is set to 1, and receive data is
transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an RXI interrupt request is
generated. Because the RXI interrupt routine reads the receive data transferred to RDR before
reception of the next receive data has finished, continuous reception can be enabled.
Serial
clock
Serial
data
RDRF
ORER
RXI interrupt request
generated

Figure 14.18 Example of SCI Operation in Reception

Transfer cannot be resumed while a receive error flag is set to 1. Accordingly, clear the ORER,
FER, PER, and RDRF bits to 0 before resuming reception. Figure 14.19 shows a sample
flowchart for serial data reception.
Bit 7
Bit 0
RDR data read and
RDRF flag cleared to 0
in RXI interrupt handling
routine
1 frame
Bit 7
Bit 0
Bit 1
RXI interrupt request
generated
Rev. 2.00, 05/03, page 563 of 820
Bit 6
Bit 7
ERI interrupt request
generated by overrun
error