Bit Bit Name
Initial Value R/W
3
STOP
0
2
AL
0
1
AAS
0
0
ADZ
0
Rev. 2.00, 05/03, page 600 of 820
Description
R/W
Stop condition detection flag
[Setting condition]
When a stop condition is detected after frame transfer
[Clearing condition]
When 0 is written in STOP after reading STOP = 1
R/W
Arbitration Lost Flag
This flag indicates that arbitration was lost in master mode.
When two or more master devices attempt to seize the bus
at nearly the same time, if the I
differing from the data it sent, it sets AL to 1 to indicate that
the bus has been taken by another master.
[Setting conditions]
•
If the internal SDA and SDA pin disagree at the rise of
SCL in master transmit mode
•
When the SDA pin outputs high in master mode while a
start condition is detected
[Clearing condition]
When 0 is written in AL/OVE after reading AL/OVE=1
R/W
Slave Address Recognition Flag
In slave receive mode, this flag is set to 1 if the first frame
following a start condition matches bits SVA6 to SVA0 in
SAR.
[Setting conditions]
•
When the slave address is detected in slave receive
mode
•
When the general call address is detected in slave
receive mode.
[Clearing condition]
When 0 is written in AAS after reading AAS=1
R/W
General Call Address Recognition Flag
This bit is valid in slave receive mode.
[Setting condition]
When the general call address is detected in slave receive
mode
[Clearing conditions]
When 0 is written in ADZ after reading ADZ=1
2
C bus interface detects data