ORER, FER, PER, and RDRF bits to 0 before resuming reception. Figure 14.9 shows a sample
flowchart for serial data reception.
Table 14.11 SSR Status Flags and Receive Data Handling
SSR Status Flag
RDRF*
ORER
1
1
0
0
0
0
1
1
1
1
0
0
1
1
Note: * The RDRF flag retains its state before data reception.
Rev. 2.00, 05/03, page 548 of 820
FER
PER
0
0
1
0
0
1
1
0
0
1
1
1
1
1
Receive Data
Lost
Transferred to RDR
Transferred to RDR
Lost
Lost
Transferred to RDR
Lost
Receive Error Type
Overrun error
Framing error
Parity error
Overrun error + framing error
Overrun error + parity error
Framing error + parity error
Overrun error + framing error +
parity error