(2) Control Signal Timing
Table 24.6 Control Signal Timing
Conditions: V
= 3.0 V to 3.6 V, AV
CC
φ = 8 MHz to 33 MHz, T
T
= –40°C to +85°C (wide-range specifications)
a
Item
RES setup time
RES pulse width
NMI setup time
NMI hold time
NMI pulse width (in recovery from
software standby mode)
IRQ setup time
IRQ hold time
IRQ pulse width (in recovery from
software standby mode)
Rev. 2.00, 05/03, page 740 of 820
= 3.0 V to 3.6 V, V
CC
= –20°C to +75°C (regular specifications),
a
Symbol
Min
t
200
RESS
t
20
RESW
t
150
NMIS
t
10
NMIH
t
200
NMIW
t
150
IRQS
t
10
IRQH
t
200
IRQW
t
RESS
Figure 24.4 Reset Input Timing
= 3.0 V to AV
ref
Max
Unit
—
ns
—
t
cyc
—
ns
—
—
—
ns
—
—
t
RESS
t
RESW
, V
= AV
= 0 V,
CC
SS
SS
Test Conditions
Figure 23.4
Figure 23.5