Timing for Counter Clearing by Compare Match/Input Capture:
Figure 12.37 shows the timing when counter clearing by compare match occurrence is specified,
and figure 12.38 shows the timing when counter clearing by input capture occurrence is specified.
φ
Compare
match signal
Counter
clear signal
TCNT
TGR
Figure 12.37 Counter Clear Timing (Compare Match)
φ
Input capture
signal
Counter clear
signal
TCNT
TGR
Rev. 1.00, 09/03, page 352 of 704
N
N
N
Figure 12.38 Counter Clear Timing (Input Capture)
H'0000
H'0000
N