Figure 16.19 Sample Serial Reception Flowchart - Renesas H8S/2437 Hardware Manual

Renesas 16-bit single-chip microcomputer h8s family / h8s / 2600 series
Table of Contents

Advertisement

Read ORER flag in SSR
Read RDRF flag in SSR
No
Read receive data in RDR and
clear RDRF flag in SSR to 0
No
All data received?
Clear RE bit in SCR to 0
[3]
Overrun error processing
Clear ORER flag in SSR to 0
Rev. 1.00, 09/03, page 464 of 704
Initialization
Start reception
ORER = 1
No
Error processing
(Continued below)
RDRF = 1
Yes
Yes
<End>
Error processing
<End>

Figure 16.19 Sample Serial Reception Flowchart

[1] SCI initialization:
[1]
The RxD pin is automatically
designated as the receive data input
pin.
[2] [3] Receive error processing:
If a receive error occurs, read the
[2]
ORER flag in SSR, and after
performing the appropriate error
Yes
processing, clear the ORER flag to 0.
[3]
Transfer cannot be resumed if the
ORER flag is set to 1.
[4] SCI status check and receive data
read:
Read SSR and check that the RDRF
[4]
flag is set to 1, then read the receive
data in RDR and clear the RDRF flag
to 0.
Transition of the RDRF flag from 0 to 1
can also be identified by an RXI
interrupt.
[5] Serial reception continuation
procedure:
To continue serial reception, before
the MSB (bit 7) of the current frame is
received, reading the RDRF flag,
reading RDR, and clearing the RDRF
[5]
flag to 0 should be finished.