Figure 16.20 Sample Flowchart Of Simultaneous Serial Transmission And Reception - Renesas H8S/2437 Hardware Manual

Renesas 16-bit single-chip microcomputer h8s family / h8s / 2600 series
Table of Contents

Advertisement

Start transmission/reception
Read TDRE flag in SSR
No
Write transmit data to TDR and
clear TDRE flag in SSR to 0
Read ORER flag in SSR
Read RDRF flag in SSR
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
No
Clear TE and RE bits in SCR to 0
Note: When switching from transmit or receive operation to simultaneous
transmit and receive operations, first clear the TE bit and RE bit to 0,
then set both these bits to 1 simultaneously.

Figure 16.20 Sample Flowchart of Simultaneous Serial Transmission and Reception

Rev. 1.00, 09/03, page 466 of 704
Initialization
TDRE = 1
Yes
ORER = 1
Error processing
No
RDRF = 1
Yes
All data received?
Yes
<End>
[1] SCI initialization:
[1]
The TxD pin is designated as the
transmit data output pin, and the RxD
pin is designated as the receive data
input pin, enabling simultaneous
transmit and receive operations.
[2]
[2] SCI status check and transmit data
write:
Read SSR and check that the TDRE
flag is set to 1, then write transmit
data to TDR and clear the TDRE flag
to 0.
Transition of the TDRE flag from 0 to
1 can also be identified by a TXI
interrupt.
[3] Receive error processing:
If a receive error occurs, read the
ORER flag in SSR, and after
performing the appropriate error
processing, clear the ORER flag to 0.
Transmission/reception cannot be
Yes
resumed if the ORER flag is set to 1.
[3]
[4] SCI status check and receive data
read:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
[4]
data in RDR and clear the RDRF flag
to 0. Transition of the RDRF flag from
0 to 1 can also be identified by an RXI
interrupt.
[5] Serial transmission/reception
continuation procedure:
To continue serial transmission/
reception, before the MSB (bit 7) of
the current frame is received, finish
reading the RDRF flag, reading RDR,
and clearing the RDRF flag to 0. Also,
before the MSB (bit 7) of the current
[5]
frame is transmitted, read 1 from the
TDRE flag to confirm that writing is
possible. Then write data to TDR and
clear the TDRE flag to 0.

Advertisement

Table of Contents
loading

Table of Contents