14.5
Operation Timing
14.5.1
TWCNT Count Timing
Figure 14.3 shows the TWCNT count timing.
Internal clock
TWCNT
input clock
TWCNT
N-1
14.5.2
TWCNT Clear Timing by Setting START Bit
Setting the START bit in TWCR2 to 1 starts duty measurement and then clears TWCNT. Figure
14.4 shows the TWCNT clear timing.
START bit
Clear signal
TWCNT
Figure 14.4 TWCNT Clear Timing by Setting START Bit
Figure 14.3 TWCNT Count Timing
N
N
Rev. 1.00, 09/03, page 407 of 704
N-1
N'00