Page 1
On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
Page 2
Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
Page 3
H8S/2628 Group FP-100B User System Interface Cable HS2628ECH61H User’s Manual Renesas Microcomputer Development Environment System Rev.4.0 2004.01...
Page 4
6. The prior written approval of Renesas Technology Corp. is necessary to reprint or reproduce in whole or in part these materials. 7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination.
Renesas) pursues a policy of continuing improvement in design, performance, functions, and safety of the user system interface cable. Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentation at any time without notice.
User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of Renesas’...
Page 7
This user's manual and user system interface cable are copyrighted and all rights are reserved by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any form, in hard-copy or machine-readable form, by any means available without Renesas’ prior written consent.
Page 8
• READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol.
Page 9
Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance.
Page 10
Thank you for purchasing this user system interface cable (HS2628ECH61H) for the Renesas’ original microcomputer H8S/2628 group. The HS2628ECH61H is a user system interface cable that connects an H8S/2628 group E6000 emulator (HS2628EPI61H; hereinafter referred to as the emulator) to the IC socket for an FP-100B...
Section 1 Configuration...1 Section 2 Connection Procedures ...3 Connecting User System Interface Cable to Emulator Station ... 3 Connecting User System Interface Cable to User System... 5 2.2.1 Installing IC Socket... 5 2.2.2 Soldering IC Socket ... 5 2.2.3 Inserting Cable Head... 6 2.2.4 Fastening Cable Head ...
Section 1 Configuration Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100B package IC socket on the user system. Figure 1 shows the configuration of the HS2628ECH61H user system interface cable for the FP-100B package. To emulator station Screws (M2.6 x 6 mm) with flat washers Socket cover...
Page 13
Table 1 lists the HS2628ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2628ECH61H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2.6 x 12 mm) Screws (M2.6 x 6 mm) Documentation Quantity Remarks...
Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
Page 15
Emulator station Cable body connector User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station...
Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
2.2.3 Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100B package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 3.
Page 18
Fasten the user system interface cable head to the IC socket for an FP-100B package on the user system with the four screws (M2.6 tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push two remove jigs. Remove jig Cable head User system Figure 4 Fastening Cable Body...
Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-100B package (IC149-100-054-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad.
Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. 29.5 17.0 63.5 Unit: mm Tolerance: ±0.5 mm Figure 6 Dimensions for User System Interface Cable Head...
Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head User system Figure 7 Resulting Dimensions after Connecting User System Interface Cable IC socket (IC149-100-054-B51 manufactured by...
Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Page 24
Screws (M2.6 x 6 mm) with flat washers Socket cover Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Figure 8 Installing MCU to User System...
Supply the external clock from the user system to the emulator by inputting the external clock from the EXTAL terminal on the cable head or connecting a crystal oscillator to the EXTAL and XTAL terminals. For details, refer to the Clock Pulse Generator section, in the H8S/2628 Group Hardware Manual.
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.
Page 27
HS2628ECH61H User's Manual Publication Date: Rev.4.00, January 29, 2004 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2004 Renesas Technology Corp. All rights reserved. Printed in Japan.
Page 28
H8S/2628 Group FP-100B User System Interface Cable HS2628ECH61H User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10B0084-0400H...