Clock Synchronous Serial Communication With Slave Select Input Function - Renesas RL78/G1P Hardware User Manual

16-bit single-chip microcontroller
Hide thumbs Also See for RL78/G1P:
Table of Contents

Advertisement

RL78/G1P

11.6 Clock Synchronous Serial Communication with Slave Select Input Function

Channel 0 of SAU0 correspond to the clock synchronous serial communication with slave select input function.
[Data transmission/reception]
 Data length of 7 or 8 bits
 Phase control of transmit/receive data
 MSB/LSB first selectable
 Level setting of transmit/receive data
[Clock control]
 Phase control of I/O clock
 Setting of transfer period by prescaler and internal counter of each channel
 Maximum transfer rate
During slave communication: Max. f
[Interrupt function]
 Transfer end interrupt/buffer empty interrupt
[Error detection flag]
 Overrun error
[Expansion function]
• Slave select function
Note Use this operation within a range that satisfies the conditions above and the AC characteristics in the
electrical specifications (see CHAPTER 27 ELECTRICAL SPECIFICATIONS).
Unit
0
Slave select input function performs the following three types of communication operations.
 Slave transmission
 Slave reception
 Slave transmission/reception
R01UH0895EJ0100 Rev.1.00
Nov 29, 2019
Note
/6
MCK
Channel
Used as CSI
0
CSI00 (supporting slave
select input function)
1
(See 11.6.1.)
(See 11.6.2.)
(See 11.6.3.)
CHAPTER 11 SERIAL ARRAY UNIT
Used as UART
UART0