Renesas RL78/G1P Hardware User Manual page 678

16-bit single-chip microcontroller
Hide thumbs Also See for RL78/G1P:
Table of Contents

Advertisement

RL78/G1P
20.10.1 A/D test register (ADTES)
This register is used to select the A/D converter's positive reference voltage, the A/D converter's negative reference
voltage, or the analog input channel (ANIxx), temperature sensor output voltage, or internal reference voltage (1.45 V) as
the target of A/D conversion.
When using the A/D test function, specify the following settings:
 Select AV
as the target of A/D conversion when converting the internal 0 V.
REFM
 Select AV
as the target of A/D conversion when converting AV
REFP
The ADTES register can be set by an 8-bit memory manipulation instruction.
Reset signal generation clears this register to 00H.
Address: F0013H
After reset: 00H
Symbol
7
ADTES
0
ADTES1
0
1
1
Other than above
Note Temperature sensor output/internal reference voltage (1.45 V) can be used only in HS (high-speed
main) mode.
R01UH0895EJ0100 Rev.1.00
Nov 29, 2019
Figure 20-16. Format of A/D Test Register (ADTES)
R/W
6
5
0
0
ADTES0
0
ANIxx/temperature sensor output
(This is specified using the analog input channel specification register (ADS).)
0
AV
REFM
1
AV
REFP
Setting prohibited
CHAPTER 20 SAFETY FUNCTIONS
.
REF
4
3
0
0
A/D conversion target
Note
/internal reference voltage (1.45 V)
2
1
0
ADTES1
ADTES0
Note
0