16.2 Registers Controlling Standby Function
The standby function is controlled by the following two registers.
 Oscillation stabilization time counter status register (OSTC)
 Oscillation stabilization time select register (OSTS)
Remark For the registers that start, stop, or select the clock, see CHAPTER 5 CLOCK GENERATOR. For registers
which control the SNOOZE mode, CHAPTER 9 A/D CONVERTER and CHAPTER 11 SERIAL ARRAY
UNIT.
R01UH0895EJ0100 Rev.1.00
Nov 29, 2019
CHAPTER 16 STANDBY FUNCTION
593