Renesas RL78/G1P Hardware User Manual page 192

16-bit single-chip microcontroller
Hide thumbs Also See for RL78/G1P:
Table of Contents

Advertisement

RL78/G1P
(b) When operation starts with slave channel output mode (TOMmp = 1) setting (PWM output))
When slave channel output mode (TOMmp = 1), the active level is determined by timer output level register m
(TOLm) setting.
TOEmp
Hi -Z
TOmp
(output)
Port output is enabled
Remarks 1. Set:
Reset: The output signal of the TOmp pin changes from active level to inactive level.
2. m: Unit number (m = 0), p: Channel number (p = 1 to 3)
R01UH0895EJ0100 Rev.1.00
Nov 29, 2019
Figure 6-33. TOmp Pin Output Status at PWM Output (TOMmp = 1)
Active
Default
status
Reset
Set
The output signal of the TOmp pin changes from inactive level to active level.
CHAPTER 6 TIMER ARRAY UNIT
Active
Active
Reset
Set
Set
TOmp bit = 0
(Default status : Low)
TOLmp bit = 0
(Active high)
TOmp bit = 1
(Default status : High)
TOmp bit = 0
(Default status : Low)
TOLmp bit = 1
(Active low)
TOmp bit = 1
(Default status : High)
173

Advertisement

Table of Contents
loading