Avaya S8700 Maintenance Manual page 1804

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-442. MEDPROPT Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
515 (e)
ANY
DSP Capacity Query test
(##1382)
769
Any
TDM NIC Loop-Around
test (#1380)
1025 (f)
Any
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. Error Type 1 - For the TN802B only, this error type indicates that less than
three DSPs are OOS (out of service), and no alarm is raised. The Aux
Data field contains the number of DSPs that are OOS.
b. Error Type 18 - the MEDPRO has been busied out by a busyout port
UUCSS command.
1. Release the port (release port UUCSS).
c. Error Type 258 - For the TN802B only, this error type indicates that more
than three, but less than 9 DSPs are OOS (out of service), and a
WARNING alarm is raised. The Aux Data field contains the number of
DSPs that are OOS.
d. Error Type 513 - For the TN2302 only, the port is OOS (out of service)
because an associated DSP is bad.
e. Error Type 515 - For the TN802B only, this error type indicates that every
DSP is OOS (out of service), and a MINOR alarm is raised. The Aux
Data field contains the number of DSPs that are OOS.
f. Error Type 1025 - The port is OOS (out of service) because of a
board-level failure. Check for errors/alarms against the board; in particular,
ping problems, IP address inconsistency, or board sanity problems.
1. Verify correct administration.
2. Check cabling and customer network before replacing circuit pack.
8-1082
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
MINOR
ON
test board UUCCSS l r5
MINOR
ON
test port UUCCSS l r10
Continued on next page
555-233-143