encryption timer

Syntax
encryption timer { update-time update-time | no-reply-timeout timeout }* slot slot-number
undo encryption timer slot slot-number
View
FTTH view
Default Level
2: System level
Parameters
update-time: Key update time, in seconds. It is in the range 1 to 255 and defaults to 10.
timeout: Encryption reply timeout time, in a unit of 100 ms. It is in the range 1 to 2550 and defaults to
30.
slot-number: Slot number of the EPON card.
Description
Use the encryption timer command to configure the key update time and encryption reply timeout
time of the encryption.
Use the undo encryption timer command to restore the key update time and encryption reply timeout
time of the encryption to the defaults.
Related command: display epon-parameter..
The encryption reply timeout time must be less than or equal to 10 times the key update time.
Examples
# Configure the key update time and encryption reply timeout time for the EPON card in slot 3 as 20
seconds and 5 seconds (50 × 100 ms) respectively.
<Sysname> system-view
[Sysname] ftth
[Sysname-ftth] encryption timer update-time 20 no-reply-timeout 50 slot 3

epon-parameter ouilist

Syntax
epon-parameter ouilist { oui oui-value oam-version version-value } &<1-9> slot slot-number
undo epon-parameter ouilist slot slot-number
View
FTTH view
Default Level
2: System level
2-20

Advertisement

Table of Contents