3HAC044266-001 Revision: -
Action
CAUTION
The motor weighs 24 kg.
All lifting accessories used must be sized
accordingly!
Apply the lifting accessory to the motor.
Note
Make sure the cable exit hole is turned the
correct way. See figure!
Lift the motor on to the guide pins and let it
hang with the outer end a little lower when
resting on the guide pins. Do not push the
motor pinion into the gear yet!
This is done in order to fit the motor with the
axis-4 motor still fitted.
Remove the lifting accessory and allow the
motor to rest on the guide pins.
Apply the rotation tool and use it to rotate
the pinion when mating it into the gear.
To release the brakes, connect the 24 VDC
power supply.
Connect to connector R2.MP3:
+ = pin 2
- = pin 5
CAUTION
Whenever parting/mating motor and gearbox,
the gears may be damaged if excessive force
is used!
© Copyright 2013 ABB. All rights reserved.
4.7.3 Replacing the axis-3 motor
Note
Lifting accessory, motor: 3HAC15534-1
xx1200001129
xx1200001131
Rotation tool: 3HAC7887-1
Continues on next page