4 Repair
4.5.2 Replacing the wrist
Continued
Connecting the axis-5 motor cables
1
2
3
Continues on next page
286
Action
Push the motor cables in through the cable
gland opening.
Refit the cable gland cover by performing
the following steps:
Slide the cable gland cover onto the
inner screw.
Refit and tighten the outer screw.
Tighten the inner screw. Make sure
that the gasket is not damaged.
Note
Replace the gasket if damaged!
Connect the connectors.
Connect in accordance with the markings
on the connectors.
© Copyright 2013 ABB. All rights reserved.
Note
xx1300000738
xx1200001016
xx1200001015
3HAC044266-001 Revision: -