4 Repair
4.4.2 Refitting the cable harness
Continued
3
4
5
6
Continues on next page
232
Action
Use caution and push the cable harness
into the wrist recess and up into the axis-6
motor.
Use caution and push the carrier into posi-
tion.
Secure the carrier with the M4 screw.
Note
The screw is located at the bottom of the
carrier.
Tip
The attachment screw securing the carrier
may be difficult to fit. Check that the carrier
is level and completely pressed against the
bottom.
Secure the cable bracket with its attach-
ment screws.