r7903
Hardware sampling times still cannot be assigned / HW t_samp free
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the number of hardware sampling times that can still be assigned.
These free sampling times can be used by OA applications such as DCC (Drive Control Chart) or FBLOCKS (free
function blocks).
Note:
OA: Open Architecture
p8500[0...7]
BI: Data transfer 0 bitwise / Transfer 0 bit
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for bitwise data transfer.
These signals are available in BO: r8510.0 ... 7 for further interconnection.
Index:
[0] = Send signal to BO: r8510.0
[1] = Send signal to BO: r8510.1
[2] = Send signal to BO: r8510.2
[3] = Send signal to BO: r8510.3
[4] = Send signal to BO: r8510.4
[5] = Send signal to BO: r8510.5
[6] = Send signal to BO: r8510.6
[7] = Send signal to BO: r8510.7
Dependency:
Refer to: r8510
p8501[0...21]
BI: Data transfer 1 bitwise / Transfer 1 bit
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32 / Binary
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for bitwise data transfer.
These signals are available in BO: r8511.0 ... 15 for further interconnection.
Index:
[0] = Send signal to BO: r8511.0
[1] = Send signal to BO: r8511.1
[2] = Send signal to BO: r8511.2
[3] = Send signal to BO: r8511.3
[4] = Send signal to BO: r8511.4
[5] = Send signal to BO: r8511.5
[6] = Send signal to BO: r8511.6
[7] = Send signal to BO: r8511.7
[8] = Send signal to BO: r8511.8
[9] = Send signal to BO: r8511.9
[10] = Send signal to BO: r8511.10
[11] = Send signal to BO: r8511.11
[12] = Send signal to BO: r8511.12
[13] = Send signal to BO: r8511.13
[14] = Send signal to BO: r8511.14
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0