Siemens SINAMICS S110 List Manual page 68

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r0207[0...4]
Rated power unit current / PU PI_rated
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
- [Arms]
Description:
Displays the rated power unit power for various load duty cycles.
Index:
[0] = Rating plate
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 cont duty cyc
[4] = S6 load duty cycle
r0208
Rated power unit line supply voltage / PU U_rated
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
- [Vrms]
Description:
Displays the rated line supply voltage of the power unit.
r0208 = 400 : 380 - 480 V +/-10 %
r0208 = 500 : 500 - 600 V +/-10 %
r0208 = 690 : 660 - 690 V +/-10 %
For the Basic Line Module (BLM) the following applies:
r0208 = 690 : 500 - 690 V +/-10 %
r0209[0...4]
Power unit, maximum current / PU I_max
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
- [Arms]
Description:
Displays the maximum output current of the power unit.
Index:
[0] = Catalog
[1] = Load duty cycle with low overload
[2] = Load duty cycle with high overload
[3] = S1 load duty cycle
[4] = S6 load duty cycle
p0210
Drive unit line supply voltage / V_connect
SERVO_S110-CAN,
Can be changed: C2(2), T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
1 [V]
Description:
Sets the drive unit supply voltage.
AC/AC unit: The rms value of the phase-to-phase line supply voltage should be entered.
DC/AC unit: The rated DC voltage of the connection busbar should be entered.
1-68
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [Arms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [Vrms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [Arms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
63000 [V]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: 8014
Unit selection: -
Expert list: 1
Factory setting
- [Arms]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [Vrms]
Access level: 2
Func. diagram: 8750, 8850,
8950
Unit selection: -
Expert list: 1
Factory setting
- [Arms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
600 [V]