p0488[0...2]
Measuring probe 1 input terminal / Meas probe 1 inp
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input terminal to connect probe 1.
Value:
0:
1:
2:
3:
7:
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0489, p0490, p0728
Note:
DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
p0489[0...2]
Measuring probe 2 input terminal / Meas probe 2 inp
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input terminal to connect probe 2.
Value:
0:
1:
2:
3:
7:
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0488, p0490, p0728
Note:
DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
p0490
Invert measuring probe or equivalent zero mark / Pr or ZM_equiv inv
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Setting to invert the digital input signals to connect a measuring probe or an equivalent zero mark.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
No measuring probe
DI/DO 9 (X132.2)
DI/DO 10 (X132.3)
DI/DO 11 (X132.4)
DI/DO 8 (X132.1)
No measuring probe
DI/DO 9 (X132.2)
DI/DO 10 (X132.3)
DI/DO 11 (X132.4)
DI/DO 8 (X132.1)
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
7
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
7
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: 4740
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 4740
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 4735, 4740
Unit selection: -
Expert list: 1
Factory setting
0000 0000 0000 0000 bin
1-121