Parameter
List of parameters
r2124[0...63]
Alarm value / Alarm value
All objects
Can be changed: -
Data type: Integer32
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays additional information about the active alarm (as integer number).
Dependency:
Refer to: r2110, r2122, r2123, r2125, r2134, r2145, r2146, r3121, r3123
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the alarm buffer and the assignment of the indices is shown in r2122.
r2125[0...63]
Alarm time removed in milliseconds / t_alarm res ms
All objects
Can be changed: -
Data type: Unsigned32
P-Group: Messages
Not for motor type: -
Min
- [ms]
Description:
Displays the system runtime in milliseconds when the alarm was cleared.
Dependency:
Refer to: r2110, r2114, r2122, r2123, r2124, r2134, r2145, r2146, r3121, r3123
Notice:
The time comprises r2146 (days) and r2125 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the alarm buffer and the assignment of the indices is shown in r2122.
p2126[0...19]
Setting fault number for acknowledge mode / Fault_no ackn_mode
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
0
Description:
Selects the faults for which the acknowledge mode is to be changed
Dependency:
Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2127
Notice:
It is not possible to re-parameterize the acknowledge mode of a fault in the following cases:
- if there is no existing fault number.
- the message type is not "fault" (F).
- when a fault is present.
p2127[0...19]
Sets acknowledgement mode / Acknowledge mode
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
1
Description:
Sets the acknowledge mode for selected fault.
Value:
1:
2:
3:
1-320
Acknowledgment only using POWER ON
Ack IMMEDIATELY after the fault cause has been removed
Acknowledgement only for PULSE INHIBIT
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [ms]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
65535
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
3
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 1750, 8065
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 1750, 8065
Unit selection: -
Expert list: 1
Factory setting
- [ms]
Access level: 3
Func. diagram: 1750, 8075
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 1750, 8075
Unit selection: -
Expert list: 1
Factory setting
1