The torque utilization is available smoothed (r0033) and unsmoothed (r0081).
The torque utilization is obtained from the required torque referred to the torque limit as follows:
- Positive torque: r0081 = ((r0079 + p1532) / (r1538 - p1532)) * 100 %
- Negative torque: r0081 = ((-r0079 + p1532) / (-r1539 + p1532)) * 100 %
The calculation of the torque utilization depends on the selected smoothing time constant (p0045).
r0082[0...2]
CO: Active power actual value / P_act
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [kW]
Description:
Displays the instantaneous active power.
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
[2] = Electric power
Dependency:
Refer to: r0032
Note:
The mechanical active power is available smoothed (r0032 with 100 ms, r0082[1] with p0045) and unsmoothed
(r0082[0]).
r0083
CO: Flux setpoint / Flex setp
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [%]
Description:
Displays the flux setpoint.
r0084
CO: Flux actual value / Flux act val
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
- [%]
Description:
Displays the flux actual value.
r0088
CO: DC link voltage setpoint / Vdc setpoint
SERVO_S110-CAN
Can be changed: -
(Tech_ctrl),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Displays, signals
(Tech_ctrl),
Not for motor type: -
SERVO_S110-PN
(Tech_ctrl)
Min
- [V]
Description:
Displays the setpoint for the DC link voltage.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: 14_5
Scaling: r2004
Max
- [kW]
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dynamic index: -
Units group: -
Scaling: PERCENT
Max
- [%]
Calculated: -
Dynamic index: -
Units group: 5_2
Scaling: p2001
Max
- [V]
Parameter
List of parameters
Access level: 3
Func. diagram: 5730
Unit selection: p0505
Expert list: 1
Factory setting
- [kW]
Access level: 3
Func. diagram: 5722
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 5722
Unit selection: -
Expert list: 1
Factory setting
- [%]
Access level: 3
Func. diagram: 8940, 8964
Unit selection: p0505
Expert list: 1
Factory setting
- [V]
1-51