Parameter
List of parameters
p0124[0...23]
Main component detection using LED / M_comp detect LED
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned8
CU_S110-PN
P-Group: Converter
Not for motor type: -
Min
0
Description:
Detection of the main components of the drive object selected via the index.
r0127[0...n]
Power unit version EPROM data / PU EPROM version
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
-
Description:
Displays the version of the EPROM data of the power unit.
Dependency:
Refer to: r0147
Note:
For parallel circuit configurations, the parameter index is assigned to a power unit.
r0128[0...n]
Power unit, firmware version / PU FW version
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
-
Description:
Displays the firmware version of the power unit.
Dependency:
Refer to: r0018, r0148, r0197, r0198
Note:
Example:
The value 1010100 should be interpreted as V01.01.01.00.
For parallel circuit configurations, the parameter index is assigned to a power unit.
p0130
Number of Motor Data Sets (MDS) / MDS count
SERVO_S110-CAN,
Can be changed: C1(3)
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Data sets
Not for motor type: -
Min
1
Description:
Sets the number of Motor Data Sets (MDS).
p0131[0...n]
Motor component number / Mot comp_no
SERVO_S110-CAN,
Can be changed: C1(4)
SERVO_S110-DP,
Data type: Unsigned8
SERVO_S110-PN
P-Group: Data sets
Not for motor type: -
Min
0
Description:
The motor data set is assigned to a motor using this parameter.
This unique component number is assigned when parameterizing the topology.
1-58
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: PDS
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: PDS
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
2
Calculated: -
Dynamic index: MDS, p0130
Units group: -
Scaling: -
Max
199
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0