Parameter
List of parameters
This parameter emulates the computing dead time of the proportionally controlled speed control loop.
The selected multiplier refers to the speed controller clock cycle (dead time= p1435 * p0115[1]).
Recommend.:
The reference model is correctly set when the characteristics of p1439 (reference model output) and p1445 (actual
speed value) are virtually identical when the I component of the speed controller is disabled.
Dependency:
In conjunction with p1433 and p1434, the characteristics (in time) of the P-controlled speed control loop can be
emulated.
For VECTOR (r0107) the following applies:
The reference model is activated with p1400.3 = 1.
Refer to: p1433, p1434
r1436
CO: Speed controller reference model speed setpoint output / RefMod n_set outp
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [rpm]
Description:
Displays the speed setpoint at the output of the reference model.
Dependency:
For VECTOR (r0107) the following applies:
The reference model is activated with p1400.3 = 1.
r1438
CO: Speed controller, speed setpoint / n_ctrl n_set
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [rpm]
Description:
Displays the speed setpoint after setpoint limiting for the P component of the speed controller.
For U/f operation, the value that is displayed is of no relevance.
Dependency:
Refer to: r1439
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
r1439
Speed setpoint, I component / n_set I_comp
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Closed-loop control
Not for motor type: REL
Min
- [rpm]
Description:
Displays the speed setpoint for the I component of the speed controller (output of the reference model after the set-
point limiting).
Dependency:
Refer to: r1438
Note:
In the standard state (the reference model is de-activated), r1438 = r1439.
1-242
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 5030, 6031
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 1550, 1590,
1700, 5030, 5040, 5042, 5210,
5300, 5620, 6031, 6040
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 3
Func. diagram: 5030, 5040,
6031
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]