Siemens SINAMICS S110 List Manual page 611

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Note:
The complete list of numbers for crosswise data comparison is listed in Fault F30611.
r9898
SI actual checksum SI parameters (processor 2) / SI act_chksm P2
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the checksum for the Safety Integrated parameters checked using checksums on processor 2 (actual
checksum).
Dependency:
Refer to: r9798, p9899
p9899
SI setpoint checksum SI parameters (processor 2) / SI setp_chksm P2
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: Unsigned32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Sets the checksum for the Safety Integrated parameters checked using checksums on processor 2 (setpoint check-
sum).
Dependency:
Refer to: p9799, r9898
r9900
Actual topology number of indices / Act topo indices
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Topology
Not for motor type: -
Min
-
Description:
Displays the number of indices of the actual topology.
Dependency:
Refer to: r9901
Note:
Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
r9901[0...n]
Actual topology / Act topo
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: Topology
Not for motor type: -
Min
-
Description:
Displays the actual topology of the drive unit.
The actual topology is sub-divided into several sections. Each of the following data is saved under an index.
General data on the topology:
- version
- attribute to compare the actual topology and target topology
- number of components
Data on a component:
- type component of the node ID of the component
- number of DRIVE-CLiQ sockets in the Node Identifier
- manufacturer and version of the Node Identifier
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: r9900
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: 2800
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 2800
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
1-611

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents