Siemens SINAMICS S110 List Manual page 728

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p20276
LVM 1 interval average value M / LVM 1 avg value M
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-340.28235E36
Description:
Setting parameter for the interval average M of instance LVM 1 of the double-sided limiter.
p20277
LVM 1 interval limit L / LVM 1 limit L
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-340.28235E36
Description:
Setting parameter for the interval limit L of instance LVM 1 of the double-sided limiter.
p20278
LVM 1 hyst HY / LVM 1 hyst HY
CU_S110-CAN,
Can be changed: T
CU_S110-DP,
Data type: FloatingPoint32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-340.28235E36
Description:
Setting parameter for hysteresis HY of instance LVM 1 of the double-sided limiter.
r20279
BO: LVM 1 input quantity above interval QU / LVM 1 X above QU
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned32
CU_S110-PN,
P-Group: -
SERVO_S110-CAN
Not for motor type: -
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Min
-
Description:
Display parameter of instance LVM 1 of the double-sided limiter that input quantity X was at least once X > M + L
and X is >= M + L - HY.
1-728
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
340.28235E36
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 1
Func. diagram: 7270
Unit selection: -
Expert list: 1
Factory setting
0.0000
Access level: 1
Func. diagram: 7270
Unit selection: -
Expert list: 1
Factory setting
0.0000
Access level: 1
Func. diagram: 7270
Unit selection: -
Expert list: 1
Factory setting
0.0000
Access level: 1
Func. diagram: 7270
Unit selection: -
Expert list: 1
Factory setting
-

Hide quick links: