Parameter
List of parameters
p1910
Motor data identification routine, stationary (standstill) / MotID standstill
SERVO_S110-CAN,
Can be changed: T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
-3
Description:
Setting to control the motor data identification with the motor stationary.
Value:
-3:
-2:
-1:
0:
1:
Recommend.:
For motors with brakes, the brake should be opened before carrying out the stationary motor data identification rou-
tine (p1215 = 2) as long as this can be done without incurring any danger. The commutation angle and the direction
of rotation are also determined.
Dependency:
Refer to: p1909, r1912, r1913, r1915, r1925, r1927, r1932, r1933, r1934, r1935, r1936, r1950, r1951
Refer to: F07990, A07991, F07993
Caution:
For motors without brake or with the brake open (p1215 = 2), for the stationary (zero speed) measurement, the
motor may rotate slightly.
Notice:
If there is a motor holding brake, it must be open (p1215 = 2).
To permanently accept the determined settings they must be saved in a non-volatile fashion (p0971, p0977).
Note:
Motor data identification can only be selected when the pulses of all of the drive objects of the Control Unit have
been suppressed. After selection, all of the other drive objects of the Control Unit are interlocked so that they can-
not be powered up until the motor data identification has been completed or de-selected.
After a started motor identification is ended, the parameter is automatically reset to 0.
A motor data identification that is presently being carried out can be terminated with p1910 = 0.
r1912
Stator resistance identified / R_stator ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
- [ohm]
Description:
Displays the identified stator resistance.
Dependency:
Refer to: p1909, p1910, r1913, r1915, r1925, r1927, r1932, r1933, r1934, r1935, r1936, r1950, r1951
r1913
Rotor time constant identified / T_rotor ident
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: PEM
Min
- [ms]
Description:
Displays the identified rotor time constant.
Dependency:
Refer to: p1909, p1910, r1912, r1915, r1925, r1927, r1932, r1933, r1934, r1935, r1936, r1950, r1951
1-270
Accept identified parameters
Acknowledge encoder inversion actual value (F07993)
Start motor data identification without acceptance
Inactive/inhibit
Start motor data identification with acceptance
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [ohm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [ms]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [ohm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [ms]