Parameter
List of parameters
r1078
CO: Total setpoint effective / Total setpoint eff
SERVO_S110-CAN
Can be changed: -
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
- [rpm]
Description:
Displays the total effective setpoint. The value indicates the sum of the effective main setpoint and supplementary
setpoint.
p1080[0...n]
Minimum speed / n_min
SERVO_S110-CAN
Can be changed: C2(1), T
(Extended set),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Setpoints
(Extended set),
Not for motor type: -
SERVO_S110-PN
(Extended set)
Min
0.000 [rpm]
Description:
Sets the lowest possible motor speed.
This value is not undershot in operation.
Note:
The parameter value applies for both motor directions.
In exceptional cases, the motor can operate below this value (e.g. when reversing).
p1082[0...n]
Maximum speed / n_max
SERVO_S110-CAN,
Can be changed: C2(1), T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Setpoints
Not for motor type: -
Min
0.000 [rpm]
Description:
Sets the highest possible speed.
Dependency:
Refer to: p0322, p0324, p0532
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in
r3996. Modifications can be made again when r3996 = 0.
Note:
The parameter applies for both motor directions. The parameter has a limiting effect and is the reference quantity
for all ramp-up and ramp-down times (e.g. down ramps, ramp-function generator, motor potentiometer).
Since the parameter is part of quick commissioning (p0010 = 1), it is defined appropriately when p0310, p0311,
p0322, p0324, p0530, p0531, and p0532 are changed.
The following limits are always effective for p1082:
p1082 <= min(p0324, p0532) if p0324 > 0 and p0532 > 0
p1082 <= p0322 if p0324 = 0 or p0532 = 0 and p0322 > 0
p1082 <= 60 / (10.0 * p0115[0] * r0313)
p1082 <= 60 * Maximum power unit pulse frequency / (5.0 * r0313)
For the automatic calculation (p0340 = 1) the value of the parameter is pre-assigned the maximum motor speed
(p0322). If p0322 = 0, the rated motor speed (p0311) is used as default (pre-assignment) value. For induction
motors that are not catalog motors (p0301 = 0), the synchronous no-load speed is used as default (pre-assignment)
value (p0310 * 60 / r0313).
1-200
Calculated: -
Dynamic index: -
Units group: 3_1
Scaling: p2000
Max
- [rpm]
Calculated: -
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
19500.000 [rpm]
Calculated: CALC_MOD_ALL
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
210000.000 [rpm]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: 3030
Unit selection: p0505
Expert list: 1
Factory setting
- [rpm]
Access level: 1
Func. diagram: 3050
Unit selection: p0505
Expert list: 1
Factory setting
0.000 [rpm]
Access level: 1
Func. diagram: 3020, 3050,
3060, 3070, 3095, 5300
Unit selection: p0505
Expert list: 1
Factory setting
1500.000 [rpm]