Note:
A fault acknowledgement is triggered with a 0/1 signal.
p2103[0...n]
BI: 1. Acknowledge faults / 1. Acknowledge
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the first signal source to acknowledge faults.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
p2104[0...n]
BI: 2. Acknowledge faults / 2. Acknowledge
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the second signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
p2105[0...n]
BI: 3. Acknowledge faults / 3. Acknowledge
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the third signal source to acknowledge faults.
Note:
A fault acknowledgement is triggered with a 0/1 signal.
p2106[0...n]
BI: External fault 1 / External fault 1
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: Messages
Not for motor type: -
Min
-
Description:
Sets the signal source for external fault 1.
Dependency:
Refer to: F07860
Note:
An external fault is triggered with a 1/0 signal.
If this fault is output at the Control Unit, then it is transferred to all existing drive objects.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: 2441, 2442,
2443, 2447, 2475, 2546, 9220,
9677, 9678
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2546, 8060
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2546, 8060
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2546
Unit selection: -
Expert list: 1
Factory setting
1
1-315