Siemens SINAMICS S110 List Manual page 18

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
Overview of parameters
Data type
The information on the data type can consist of the following two items (separated
by a slash):
• First item
Data type of the parameter
• Second item (for binector or connector input only)
Data type of the signal source to be interconnected (binector/connector out-
put)
Parameters can have the following data types:
• I8
• I16
• I32
• U8
• U16
• U32
• Float
Depending on the data type of the BICO input parameter (signal sink) and BICO
output parameter (signal source), the following combinations are possible when
BICO interconnections are established:
Table 1-2
Possible combinations of BICO interconnections
BICO output parameter
CO: Unsigned8
CO: Unsigned16
CO: Integer16
CO: Unsigned32
CO: Integer32
CO: FloatingPoint32
BO: Unsigned8
BO: Unsigned16
Legend:
1 Exception:
BICO input parameters with data type "Unsigned32/FloatingPoint32" can also be interconnected with the following
BICO output parameters, despite the fact that these are not of the "FloatingPoint32" data type:
CO: r2050, CO: r2060
1-18
Integer8
Integer16
Integer32
Unsigned8
Unsigned16
Unsigned32
FloatingPoint32
CI parameter
Unsigned32/
Unsigned32/
Integer16
Integer32
x
x
x
x
x
x
x: BICO interconnection permitted
–: BICO interconnection not permitted
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
8-bit integer
16-bit integer
32-bit integer
8 bits without sign
16 bits without sign
32 bits without sign
32-bit floating point number
BICO input parameter
Unsigned32/
FloatingPoint32
x
x
x
x
x
1
x
x
© Siemens AG 2012 All Rights Reserved
BI parameter
Unsigned32/
Binary
x
x

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents