Parameter
List of parameters
05
Feedback signal contactor 5
06
Feedback signal contactor 6
07
Feedback signal contactor 7
08
Feedback signal contactor 8
09
Feedback signal contactor 9
10
Feedback signal contactor 10
11
Feedback signal contactor 11
12
Feedback signal contactor 12
13
Feedback signal contactor 13
14
Feedback signal contactor 14
15
Feedback signal contactor 15
Dependency:
Refer to: p0831
p0833
Data set changeover configuration / DS_chng config
SERVO_S110-CAN,
Can be changed: C2(15)
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Data sets
Not for motor type: -
Min
-
Description:
Sets the configuration for the motor and encoder changeover.
Bit field:
Bit
Signal name
00
Contactor changeover from the applica-
tion/drive
01
Pulse suppression by application/drive
02
Suppress drive parking for EDS changeover Yes
Note:
Re bit 00:
When the bit is set and the motor has to be changed over, then p0827 must be set differently in the appropriate
motor data sets.
Re bit 02:
The bit defines whether, for an EDS changeover, the status signal Gn_ZSW.14 is suppressed (parking encoder
active).
r0835.0...11
CO/BO: Data set changeover status word / DDS_ZSW
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: Unsigned16
SERVO_S110-PN
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Displays the status word for the drive data set changeover.
Bit field:
Bit
Signal name
00
Motor changeover active
01
Encoder changeover active
02
Internal parameter calculation active
04
Armature short circuit active
05
Identification running
06
Friction characteristic record running
07
Rotating measurement running
08
Motor data identification running
10
Wait for pulse suppression
11
Wait for motor changeover feedback signal
Note:
This parameter is only supplied with up-to-date values if data set changeover has been selected or is running.
Re bit 00:
The signal is only influenced when a motor changeover is set via p0827 (unequal bit numbers).
1-164
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
application
application
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Opened
-
Opened
-
Opened
-
Opened
-
Opened
-
Opened
-
Opened
-
Opened
-
Opened
-
Opened
-
Opened
-
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
Drive
-
Drive
-
No
-
Access level: 2
Func. diagram: 8575
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
FP
No
8575
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-
No
-