Siemens SINAMICS S110 List Manual page 424

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
p3054[0...n]
MotId rotor resistance identified / R_rotor ident
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: PEM, REL
Min
0.00000 [ohm]
Description:
Rotor resistance for an induction motor determined by the motor data identification.
This stator resistance can be changed after the identification and accepted in p0354 with p1910/p1960 = -3.
Dependency:
Refer to: p0354, p0625, p1910, r1927, p1960
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
p3056[0...n]
MotId stator leakage inductance identified / L_stator leak
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: -
Min
0.00000 [mH]
Description:
Stator leakage inductance determined by the motor data identification.
This stator leakage inductance can be changed after the identification and accepted in p0356 with p1910/p1960 = -
3.
Dependency:
Refer to: p0356, p1910, r1932
p3058[0...n]
MotId rotor leakage inductance identified / L_rotor leak
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: PEM, REL
Min
0.00000 [mH]
Description:
Rotor leakage induction for an induction motor determined by the motor data identification.
This rotor leakage inductance can be changed after the identification and accepted in p0358 with p1910/p1960 = -3.
Dependency:
Refer to: p0358, p1910, r1932
p3060[0...n]
MotId magnetizing inductance identified / MotId Lh ident
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor identification
Not for motor type: PEM, REL
Min
0.00000 [mH]
Description:
Magnetizing inductance for an induction motor determined by the motor data identification.
This magnetizing inductance can be changed after the identification and accepted in p0360 with p1910/p1960 = -3.
Dependency:
Refer to: p0360, p1910, r1936, p1960
1-424
Calculated: CALC_MOD_ALL
Dynamic index: MDS, p0130
Units group: 16_1
Scaling: -
Max
300.00000 [ohm]
Calculated: CALC_MOD_ALL
Dynamic index: MDS, p0130
Units group: 15_1
Scaling: -
Max
1000.00000 [mH]
Calculated: CALC_MOD_ALL
Dynamic index: MDS, p0130
Units group: 15_1
Scaling: -
Max
1000.00000 [mH]
Calculated: CALC_MOD_ALL
Dynamic index: MDS, p0130
Units group: 15_1
Scaling: -
Max
10000.00000 [mH]
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 3
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
0.00000 [ohm]
Access level: 3
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
0.00000 [mH]
Access level: 3
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
0.00000 [mH]
Access level: 3
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
0.00000 [mH]

Hide quick links:

Advertisement

Table of Contents
loading