Siemens SINAMICS S110 List Manual page 571

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

p9542
SI Motion act. val. comparison tolerance (crossw.) (processor 1) / SI Mtn act tol P1
SERVO_S110-CAN,
Can be changed: C2(95)
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.0010 [mm]
Description:
Sets the tolerance for the cross-check of the actual position between the two monitoring channels.
For encoderless motion monitoring functions, the tolerance must be set to a higher value (12 degrees rotary and 1
mm linear).
Dependency:
Refer to: C01711
p9542
SI Motion act. val. comparison tolerance (crossw.) (processor 1) / SI Mtn act tol P1
SERVO_S110-CAN
Can be changed: C2(95)
(Safety rot),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Safety Integrated
(Safety rot),
Not for motor type: -
SERVO_S110-PN
(Safety rot)
Min
0.0010 [°]
Description:
Sets the tolerance for the cross-check of the actual position between the two monitoring channels.
For encoderless motion monitoring functions, the tolerance must be set to a higher value (12 degrees rotary and 1
mm linear).
Dependency:
Refer to: C01711
p9544
SI Motion actual value comparison tolerance (referencing) (P1) / SI Mtn ref tol P1
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Safety Integrated
Not for motor type: -
Min
0.0000 [mm]
Description:
Sets the tolerance to check the actual values after referencing (incremental encoder) or when powering up (abso-
lute encoder).
Dependency:
Refer to: C01711
Note:
A change only becomes effective after a POWER ON.
p9544
SI Motion actual value comparison tolerance (referencing) (P1) / SI Mtn ref tol P1
SERVO_S110-CAN
Can be changed: U, T
(Safety rot),
Data type: FloatingPoint32
SERVO_S110-DP
P-Group: Safety Integrated
(Safety rot),
Not for motor type: -
SERVO_S110-PN
(Safety rot)
Min
0.0000 [°]
Description:
Sets the tolerance to check the actual values after referencing (incremental encoder) or when powering up (abso-
lute encoder).
Dependency:
Refer to: C01711
Note:
A change only becomes effective after a POWER ON.
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
360.0000 [mm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
360.0000 [°]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
36.0000 [mm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
36.0000 [°]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.1000 [mm]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.1000 [°]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.0100 [mm]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.0100 [°]
1-571