Siemens SINAMICS S110 List Manual page 486

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Parameter
List of parameters
r7850[0...23]
Drive object operational/not operational / DO ready for oper
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Integer16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
-32786
Description:
Displays whether, for an activated drive object, all activated topology components are available or not (or whether
these can be addressed).
0: Drive object not ready for operation
1: Drive object ready for operation
p7852
Number of indices for r7853 / Qty indices r7853
CU_S110-CAN,
Can be changed: U, T
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
1
Description:
Displays the number of indices for r7853[0...n].
This corresponds to the number of DRIVE-CLiQ components that are in the target topology.
Dependency:
Refer to: r7853
Note:
The values are valid if all available Control Units adopt the "Initialization finished" state (r3988 = 800) following
power-up.
r7853[0...n]
Component available/not available / Comp present
CU_S110-CAN,
Can be changed: -
CU_S110-DP,
Data type: Unsigned16
CU_S110-PN
P-Group: -
Not for motor type: -
Min
0000 hex
Description:
Displays the component and whether this component is currently present.
High byte: Component number
Low byte: 0/1 (not available/available)
Dependency:
Refer to: p7852
Note:
The values are valid if all available Control Units adopt the "Initialization finished" state (r3988 = 800) following
power-up.
p7857
Sub-boot mode / Sub-boot mode
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
0
Description:
Sets the mode for the sub-boot.
Value:
0:
1:
Note:
For p7857 = 0 (manual sub-boot) the following applies:
The parameter should be set to 1 to start the sub-boot.
1-486
Sub-boot manual
Sub-boot automatic
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
32767
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
200
Calculated: -
Dynamic index: p7852
Units group: -
Scaling: -
Max
FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1