Parameter
List of parameters
p0233
Power unit motor reactor / PU mot reactor
SERVO_S110-CAN,
Can be changed: C2(2), U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
0.000 [mH]
Description:
Enter the inductance of a filter connected at the power unit output.
Dependency:
This parameter is automatically pre-set when you select a filter via p0230 if a SIEMENS filter is defined for the
power unit.
Note:
The parameter cannot be changed if the power unit has an internal sine-wave filter.
p0234
Power unit sine-wave filter capacitance / PU sine filter C
SERVO_S110-CAN,
Can be changed: C2(2), U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
0.000 [µF]
Description:
Enters the capacitance of a sine-wave filter connected at the power unit output.
Dependency:
This parameter is automatically pre-set when you select a filter via p0230 if a SIEMENS filter is defined for the
power unit.
Note:
The parameter value includes the sum of all of the capacitances of a phase connected in series (phase - ground).
The parameter cannot be changed if the power unit has an internal sine-wave filter.
r0238
Internal power unit resistance / PU R internal
SERVO_S110-CAN,
Can be changed: -
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
- [ohm]
Description:
Displays the internal resistance of the power unit (IGBT and line resistance).
Note:
For a parallel circuit, the value corresponds to the resistance of a power unit.
p0249
Power unit cooling type / PU cool type
SERVO_S110-CAN,
Can be changed: C2(1, 2)
SERVO_S110-DP,
Data type: Integer16
SERVO_S110-PN
P-Group: Converter
Not for motor type: -
Min
0
Description:
Sets the cooling type for booksize compact power units.
This therefore defines whether for these power units, the internal air cooling is shut down and instead, the "Cold-
Plate" cooling type is used.
Value:
0:
1:
Note:
For booksize compact power units, there is a 4 at the 5th position in the Order No.
The parameter is irrelevant for all other power unit types.
1-70
Air cooling int
Cold-Plate
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000.000 [mH]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1000.000 [µF]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
- [ohm]
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
1
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.000 [mH]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.000 [µF]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [ohm]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0