p0356[0...n]
Motor stator leakage inductance / Mot L_stator leak.
SERVO_S110-CAN,
Can be changed: C2(3), U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: -
Min
0.00000 [mH]
Description:
Induction motor, separately-excited synchronous motor: Sets the rotor leakage inductance of the motor.
Synchronous motor: Sets the stator quadrature axis inductance of the motor.
This parameter value is automatically calculated using the motor model (p0340 = 1, 2) or using the motor identifica-
tion routine (p1910).
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note:
The reference value for p0326 is inversely proportional to the leakage inductance of the motor (p0353, p0354,
p0356).
p0358[0...n]
Motor rotor leakage inductance / damping inductance, d axis / Mot L_r leak / LDd
SERVO_S110-CAN,
Can be changed: C2(3), U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: PEM, REL
Min
0.00000 [mH]
Description:
Sets the rotor/secondary section leakage inductance of the motor.
For separately-excited synchronous motors: Sets the damping inductance in the rotor direction (d-axis).
This value is automatically calculated using the motor model (p0340 = 1, 2) or using the motor identification routine
(p1910) (not for separately-excited synchronous motors).
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
VECTOR:
If the rotor leakage inductance (p0358) for induction motors is changed outside the commissioning phase (p0010 >
0), then the magnetizing inductance (p0360) is automatically adapted to the new EMF (r0337). You are then
advised to repeat the measurement for the saturation characteristic (p1960).
p0360[0...n]
Motor magnetizing inductance/magn. inductance, d axis saturated / Mot Lh/Lh d sat
SERVO_S110-CAN,
Can be changed: C2(3), U, T
SERVO_S110-DP,
Data type: FloatingPoint32
SERVO_S110-PN
P-Group: Motor
Not for motor type: PEM, REL
Min
0.00000 [mH]
Description:
Sets the magnetizing inductance of the motor.
For separately-excited synchronous motors: Sets the saturated magnetizing inductance in the rotor direction (d-
axis).
This parameter value is automatically calculated using the motor model (p0340 = 1, 2) or using the motor identifica-
tion routine (p1910) (not for separately-excited synchronous motors).
Caution:
When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated: CALC_MOD_EQU
Dynamic index: MDS, p0130
Units group: 15_1
Scaling: -
Max
1000.00000 [mH]
Calculated: CALC_MOD_EQU
Dynamic index: MDS, p0130
Units group: 15_1
Scaling: -
Max
1000.00000 [mH]
Calculated: CALC_MOD_EQU
Dynamic index: MDS, p0130
Units group: 15_1
Scaling: -
Max
10000.00000 [mH]
Parameter
List of parameters
Access level: 3
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
0.00000 [mH]
Access level: 3
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
0.00000 [mH]
Access level: 3
Func. diagram: -
Unit selection: p0349
Expert list: 1
Factory setting
0.00000 [mH]