p2142[0...n]
Hysteresis speed 1 / n_hysteresis 1
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
SERVO_S110-PN
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [rpm]
Description:
Sets the hysteresis speed (bandwidth) for the signal "f or n / v comparison value reached or exceeded" (BO:
r2199.1).
Dependency:
Refer to: p2141, r2199
p2144[0...n]
BI: Motor stall monitoring enable (negated) / Mot stall enab neg
SERVO_S110-CAN,
Can be changed: U, T
SERVO_S110-DP,
Data type: Unsigned32 / Binary
SERVO_S110-PN
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the negated enable (0 = enable) of the motor stall monitoring.
Dependency:
Refer to: p2163, p2164, p2166, r2197, r2198
Refer to: F07900
Note:
If the enable signal is connected to r2197.7 then the stall signal is suppressed if there is no speed setpoint - actual
value deviation.
r2145[0...63]
Alarm time received in days / t_alarm recv days
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the system runtime in days when the alarm occurred.
Dependency:
Refer to: r2110, r2114, r2122, r2123, r2124, r2125, r2134, r2146, r3121, r3123
Notice:
The time comprises r2145 (days) and r2123 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2146[0...63]
Alarm time removed in days / t_alarm res days
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Not for motor type: -
Min
-
Description:
Displays the system runtime in days when the alarm was cleared.
Dependency:
Refer to: r2110, r2114, r2122, r2123, r2124, r2125, r2134, r2145, r3121, r3123
Notice:
The time comprises r2146 (days) and r2125 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Calculated:
CALC_MOD_LIM_REF
Dynamic index: DDS, p0180
Units group: 3_1
Scaling: -
Max
300.00 [rpm]
Calculated: -
Dynamic index: CDS, p0170
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Scaling: -
Max
-
Parameter
List of parameters
Access level: 3
Func. diagram: 8010
Unit selection: p0505
Expert list: 1
Factory setting
2.00 [rpm]
Access level: 3
Func. diagram: 8012
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 8065
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: 8065
Unit selection: -
Expert list: 1
Factory setting
-
1-325